| 5-1 Operating temperature range..................... | 0℃ ~ 60℃ |
| 5-2 Operating humidity range..................... | 20 ~ 90%RH |
| 5-3 Storage temperature range..................... | -20℃ ~ 70℃ |
| 5-4 Storage humidity range..................... | Less than 95% RH |
| 5-5.Rated voltage..................... | AC 1Vrms ( 1KHz ) |
| 5-6. Rated power..................... | 0.3mW |
| 5-7.Standard characteristic Fig-3.................. | 65KΩ(at25℃, 60% RH) |
| 5-8.Response time Fig-4..................... | < 30Sec |
| 5-8 Accuracy..................... | < ± 5% RH |
| 5-9.Hysteresis..................... | Within 3% RH |
| 5-10.Temperture characteristic Fig-5 |
|
6-1. Soldering heat resistance
The Humidity Sensor should be kept its original appearance and electrical Characteristics after soldered for 3 seconds at 270 ± 5℃ temperature condition. |
|
|
6-2. Termination strength
The lead terminal should be safe after pulled with it by 500g force for 10 seconds. |
|
|
6-3. Shock resistance
The Humidity Sensor should be kept its original appearance and electrical characteristic after falling down 5 times on the hard place from 70cm height. |
|
|
6-4. Vibration resistance
The Humidity Sensor should be kept its original appearance and electrical 10-55Hz characteristic after testing the vibration for 2 hours in each direction (X.Y.Z) frequency in the box (10 × 60 × 10) |
|
7-1. Humidity resistance
Put it for 1000 hours at 40℃ and 90% RH, put it more for 1 hour in usual humidity and temperature conditions. After that, the value is changed within ±3% RH from the initial value . |
|
|
7-2. Humidity cycle
One cycle should be to put for 30 minutes at 25℃and 30% RH continue to put it for 30 minutes while raising to 90% RH, put it for 30 minutes at 90% RH and put it more for 30minutes while lowering to 30% RH. Repeat 500 these cycles, usual humidity and temperature conditions. After that, the value is changed within ±5% RH from the initial value. |
|
|
7-3. Temperature cycle
One cycle should be to put for 30 minutes at -30℃ continue to put it for 30 minutes while raising the temperature to 85℃, put it for 30 minutes at 85℃ and put it more for 30 minutes while lowering the temperature to - 30℃. Repeat these cycles 100 times, then put it for 1 hour in usual condition. After that, the value is not changed out of ±5% RH from the initial value. |
|
|
7-4. Heat resistance
Put it for 1000 hours at 80℃ and 30% RH, and put it more for 1 hour in usual humidity and temperature conditions. After that, the value is not changed out of ± 5% RH from the initial value. |
|
|
7-5. Cool resistance
Put it for 1000 hours at -30℃, put it more for 1 hour in usual humidity and temperature conditions. After that, the value is not changed out of ± 5% RH from the initial value. |
|
8-1
Please beware of using the following gas. * Solvent, Organic gas, Alcohol, Glycol. * NOx, ammonia inorganic gas, sox. * Anionic ionizer, salty air. |
|
|
8-2
Do not use it in too much wet or condensed condition. |
|
|
8-3
Do not use DC to the Humidity Sensor. |
|
|
8-4
Use in good air condition. |